10 Easy Steps: How to Test Gas Valve Coils on a Dryer

10 Easy Steps: How to Test Gas Valve Coils on a Dryer

$title$

Gasoline dryer valves are a vital a part of the equipment’s operation. They open and shut to permit fuel to movement to the burner, which heats the air that dries your garments. If the valve fails, the dryer won’t be able to warmth correctly. On this article, we’ll present you the best way to take a look at a fuel valve coil on a dryer. It is a easy course of that may be accomplished in a couple of minutes.

**Earlier than you start,** ensure that the dryer is disconnected from the facility provide. Additionally, you will want a multimeter, which is a tool used to measure electrical present. After getting gathered your supplies, comply with these steps:

1. **Find the fuel valve.** It’s normally situated on the again of the dryer, close to the burner.
2. **Disconnect the wires from the fuel valve coil.** There are normally two wires, one black and one white.
3. **Set your multimeter to the ohms setting.**
4. **Contact the probes of the multimeter to the terminals of the fuel valve coil.** The studying must be between 200 and 1000 ohms.
5. **If the studying isn’t inside this vary,** the fuel valve coil is flawed and must be changed.

Methods to Check Gasoline Valve Coils on a Dryer

In case your dryer isn’t heating, one of many potential causes could possibly be a defective fuel valve coil. Testing the fuel valve coils is a comparatively easy activity that may be accomplished with a multimeter. Comply with these steps to check the fuel valve coils in your dryer:

  1. Unplug the dryer from the facility outlet.
  2. Take away the entry panel to the dryer’s fuel valve.
  3. Find the fuel valve coils. There must be two coils, one for the principle burner and one for the pilot mild.
  4. Disconnect the wires from the fuel valve coils.
  5. Set your multimeter to the ohms setting.
  6. Contact one probe of the multimeter to every terminal on the fuel valve coil. The multimeter ought to learn between 100 and 200 ohms.
  7. If the multimeter reads 0 ohms, the fuel valve coil is shorted and must be changed.
  8. If the multimeter reads infinity, the fuel valve coil is open and must be changed.

Individuals Additionally Ask

What are the signs of a defective fuel valve coil?

The signs of a defective fuel valve coil can embrace:

  • The dryer not heating
  • The pilot mild not staying lit
  • The dryer making a clicking noise
  • The dryer overheating

How do I exchange a fuel valve coil?

To interchange a fuel valve coil, comply with these steps:

  1. Shut off the fuel provide to the dryer.
  2. Unplug the dryer from the facility outlet.
  3. Take away the entry panel to the dryer’s fuel valve.
  4. Find the fuel valve coils. There must be two coils, one for the principle burner and one for the pilot mild.
  5. Disconnect the wires from the fuel valve coils.
  6. Take away the mounting screws that maintain the fuel valve coils in place.
  7. Set up the brand new fuel valve coils.
  8. Reconnect the wires to the fuel valve coils.
  9. Reinstall the entry panel to the dryer’s fuel valve.
  10. Activate the fuel provide to the dryer.
  11. Plug the dryer again into the facility outlet.

How a lot does it value to switch a fuel valve coil?

The associated fee to switch a fuel valve coil will range relying on the make and mannequin of your dryer. Nonetheless, you may anticipate to pay between $50 and $150 for the half and labor.